{"product_id":"diagnostic-audiometer-ac9083","title":"Diagnostic audiometer AC9083","description":"\u003ch2 data-start=\"170\" data-end=\"194\"\u003e Medical Device Name\u003c\/h2\u003e\n\n\u003cp data-start=\"195\" data-end=\"226\"\u003e \u003cstrong data-start=\"195\" data-end=\"226\"\u003eNon-Mydriatic Fundus Camera\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003chr data-start=\"228\" data-end=\"231\"\u003e\n\n\u003ch2 data-start=\"233\" data-end=\"253\"\u003e Basic Information\u003c\/h2\u003e\n\n\u003cp data-start=\"255\" data-end=\"432\"\u003e \u003cstrong data-start=\"255\" data-end=\"265\"\u003eBrand:\u003c\/strong\u003e Topcon (Japan)\u003cbr data-start=\"280\" data-end=\"283\"\u003e \u003cstrong data-start=\"283\" data-end=\"293\"\u003eModel:\u003c\/strong\u003e TRC-NW300\u003cbr data-start=\"303\" data-end=\"306\"\u003e \u003cstrong data-start=\"306\" data-end=\"330\"\u003eManufacture Year:\u003c\/strong\u003e 2013\u003cbr data-start=\"335\" data-end=\"338\"\u003e \u003cstrong data-start=\"338\" data-end=\"355\"\u003eManufacturer:\u003c\/strong\u003e Topcon Corporation\u003cbr data-start=\"374\" data-end=\"377\"\u003e \u003cstrong data-start=\"377\" data-end=\"391\"\u003eCondition:\u003c\/strong\u003e Pre-Owned\u003cbr data-start=\"401\" data-end=\"404\"\u003e \u003cstrong data-start=\"404\" data-end=\"421\"\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/p\u003e\n\n\u003chr data-start=\"434\" data-end=\"437\"\u003e\n\n\u003ch2 data-start=\"439\" data-end=\"458\"\u003e Product Overview\u003c\/h2\u003e\n\n \u003cp data-start=\"460\" data-end=\"711\"\u003eThe TRC-NW300 non-mydriatic fundus camera is equipped with a high-resolution digital camera, providing high-quality fundus color images. It supports multiple imaging modes, including color photography, red-free imaging, FFA, ICG, and autofluorescence.\u003c\/p\u003e\n\n\u003cp data-start=\"713\" data-end=\"935\"\u003e The system supports small-pupil imaging, making it suitable for elderly patients and patients with irregular pupils.\u003cbr data-start=\"829\" data-end=\"832\"\u003e Its ergonomic body design and touch-screen operation panel enable easier and more convenient operation.\u003c\/p\u003e\n\n\u003cp data-start=\"937\" data-end=\"1075\"\u003e The device integrates seamlessly with IMAGEnet image processing software, facilitating data acquisition, processing, backup, and analysis.\u003c\/p\u003e\n\n\u003chr data-start=\"1077\" data-end=\"1080\"\u003e\n\n\u003ch2 data-start=\"1082\" data-end=\"1101\"\u003e Product Features \u003c\/h2\u003e\n\n\u003cul data-start=\"1103\" data-end=\"1661\"\u003e\n\n\u003cli data-start=\"1103\" data-end=\"1174\"\u003e\n\n\u003cp data-start=\"1105\" data-end=\"1174\"\u003e Built-in 8-megapixel CCD camera for clear and natural fundus images \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1175\" data-end=\"1258\"\u003e\n\n\u003cp data-start=\"1177\" data-end=\"1258\"\u003e Integrated design with no external cables, allowing easy movement of the device \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1259\" data-end=\"1380\"\u003e\n\n\u003cp data-start=\"1261\" data-end=\"1380\"\u003e Automatic focusing, automatic exposure, and automatic image capture simplify operation and improve imaging efficiency\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1381\" data-end=\"1538\"\u003e\n\n \u003cp data-start=\"1383\" data-end=\"1538\"\u003eOptimized exposure parameter settings reduce flash intensity and minimize pupil stimulation, improving patient comfort and increasing image repeatability \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1539\" data-end=\"1584\"\u003e\n\n\u003cp data-start=\"1541\" data-end=\"1584\"\u003e Compatible with Windows operating systems \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1585\" data-end=\"1661\"\u003e\n\n\u003cp data-start=\"1587\" data-end=\"1661\"\u003e Supports real-time image viewing and storage via CF card or Memory Stick \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"1663\" data-end=\"1666\"\u003e\n\n\u003ch2 data-start=\"1668\" data-end=\"1708\"\u003e TRC-NW300 Non-Mydriatic Fundus Camera\u003c\/h2\u003e\n\n\u003cp data-start=\"1710\" data-end=\"1913\"\u003e The TRC-NW300 features a high-resolution digital camera capable of producing high-quality fundus color images. It offers multiple imaging modes, including color, red-free, FFA, ICG, and autofluorescence.\u003c\/p\u003e\n\n\u003cp data-start=\"1915\" data-end=\"2074\"\u003e Small-pupil imaging capability makes it suitable for elderly patients and those with irregular pupils.\u003cbr data-start=\"2017\" data-end=\"2020\"\u003e The touch-screen operation panel enhances ease of use.\u003c\/p\u003e\n\n\u003cp data-start=\"2076\" data-end=\"2216\"\u003e The system works seamlessly with IMAGEnet image processing software, enabling efficient image acquisition, processing, backup, and analysis.\u003c\/p\u003e\n\n\u003chr data-start=\"2218\" data-end=\"2221\"\u003e\n\n\u003ch2 data-start=\"2223\" data-end=\"2255\"\u003e TRC-NW300 Key Characteristics \u003c\/h2\u003e\n\n\u003cul data-start=\"2257\" data-end=\"2717\"\u003e\n\n\u003cli data-start=\"2257\" data-end=\"2333\"\u003e\n\n\u003cp data-start=\"2259\" data-end=\"2333\"\u003e Built-in 8-megapixel CCD camera for clear and natural fundus photography \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2334\" data-end=\"2420\"\u003e\n\n\u003cp data-start=\"2336\" data-end=\"2420\"\u003e All-in-one integrated design without external wiring, facilitating device mobility\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2421\" data-end=\"2504\"\u003e\n\n \u003cp data-start=\"2423\" data-end=\"2504\"\u003eAutomatic focus, exposure, and image capture for simple and efficient operation \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2505\" data-end=\"2585\"\u003e\n\n\u003cp data-start=\"2507\" data-end=\"2585\"\u003e Reduced flash intensity to minimize pupil impact and enhance patient comfort \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2586\" data-end=\"2618\"\u003e\n\n\u003cp data-start=\"2588\" data-end=\"2618\"\u003e Improved image repeatability \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2619\" data-end=\"2717\"\u003e\n\n\u003cp data-start=\"2621\" data-end=\"2717\"\u003e Windows-compatible system with real-time image viewing and storage via CF card or Memory Stick\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Revive Med Lab","offers":[{"title":"Default Title","offer_id":45839432712353,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/9620\/1633\/files\/20260327160906_792_153.jpg?v=1774600568","url":"https:\/\/www.revivemedlab.com\/products\/diagnostic-audiometer-ac9083","provider":"Reco Link","version":"1.0","type":"link"}