{"product_id":"twelve-channel-automatic-analysis-electrocardiograph-fx-7402","title":"MetriScan Finger Bone Densitometer","description":"\u003ch2 data-start=\"128\" data-end=\"152\"\u003e Medical Device Name\u003c\/h2\u003e\n\n\u003cp data-start=\"153\" data-end=\"196\"\u003e \u003cstrong data-start=\"153\" data-end=\"196\"\u003e12-Channel Automatic Electrocardiograph\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003chr data-start=\"198\" data-end=\"201\"\u003e\n\n\u003ch2 data-start=\"203\" data-end=\"223\"\u003e Basic Information\u003c\/h2\u003e\n\n \u003cp data-start=\"225\" data-end=\"446\"\u003e\u003cstrong data-start=\"225\" data-end=\"235\"\u003eBrand:\u003c\/strong\u003e Fukuda Electronics\u003cbr data-start=\"254\" data-end=\"257\"\u003e \u003cstrong data-start=\"257\" data-end=\"267\"\u003eModel:\u003c\/strong\u003e FX-7402\u003cbr data-start=\"275\" data-end=\"278\"\u003e \u003cstrong data-start=\"278\" data-end=\"302\"\u003eDate of Manufacture:\u003c\/strong\u003e July 2014\u003cbr data-start=\"312\" data-end=\"315\"\u003e \u003cstrong data-start=\"315\" data-end=\"332\"\u003eManufacturer:\u003c\/strong\u003e Beijing Fukuda Electronics Medical Instrument Co., Ltd.\u003cbr data-start=\"388\" data-end=\"391\"\u003e \u003cstrong data-start=\"391\" data-end=\"405\"\u003eCondition:\u003c\/strong\u003e Pre-Owned\u003cbr data-start=\"415\" data-end=\"418\"\u003e \u003cstrong data-start=\"418\" data-end=\"435\"\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/p\u003e\n\n\u003chr data-start=\"448\" data-end=\"451\"\u003e\n\n\u003ch2 data-start=\"453\" data-end=\"477\"\u003e Display \u0026amp; Acquisition \u003c\/h2\u003e\n\n\u003cul data-start=\"479\" data-end=\"606\"\u003e\n\n\u003cli data-start=\"479\" data-end=\"524\"\u003e\n\n\u003cp data-start=\"481\" data-end=\"524\"\u003e 5.6-inch LCD touch display with backlight \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"525\" data-end=\"606\"\u003e\n\n\u003cp data-start=\"527\" data-end=\"606\"\u003e Twelve-lead synchronous acquisition and recording, standard 12-lead recording \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"608\" data-end=\"611\"\u003e\n\n\u003ch2 data-start=\"613\" data-end=\"638\"\u003e Electrical Performance \u003c\/h2\u003e\n\n\u003cul data-start=\"640\" data-end=\"998\"\u003e\n\n\u003cli data-start=\"640\" data-end=\"675\"\u003e\n\n\u003cp data-start=\"642\" data-end=\"675\"\u003e Input impedance: \u0026gt;50 MΩ (10 Hz) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"676\" data-end=\"709\"\u003e\n\n\u003cp data-start=\"678\" data-end=\"709\"\u003e Input circuit current: \u0026lt;50 nA \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"710\" data-end=\"753\"\u003e\n\n\u003cp data-start=\"712\" data-end=\"753\"\u003e Frequency response: 0.05–150 Hz (-3 dB) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"754\" data-end=\"805\"\u003e\n\n\u003cp data-start=\"756\" data-end=\"805\"\u003e Gain: 1\/4, 1\/2, 1, 2 cm\/mV, manual or automatic \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"806\" data-end=\"853\"\u003e\n\n\u003cp data-start=\"808\" data-end=\"853\"\u003e Common mode rejection ratio (CMRR): \u0026gt;103 dB \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"854\" data-end=\"892\"\u003e\n\n\u003cp data-start=\"856\" data-end=\"892\"\u003e Anti-polarization voltage: \u0026gt;550 mV \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"893\" data-end=\"956\"\u003e\n\n\u003cp data-start=\"895\" data-end=\"956\"\u003e Defibrillation protection with anti-defibrillation function \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"957\" data-end=\"998\"\u003e\n\n\u003cp data-start=\"959\" data-end=\"998\"\u003e Time constant: 3.2 seconds (0 ~ +20%) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"1000\" data-end=\"1003\"\u003e\n\n\u003ch2 data-start=\"1005\" data-end=\"1025\"\u003e Signal Processing \u003c\/h2\u003e\n\n\u003cul data-start=\"1027\" data-end=\"1177\"\u003e\n\n\u003cli data-start=\"1027\" data-end=\"1106\"\u003e\n\n \u003cp data-start=\"1029\" data-end=\"1106\"\u003eFilters: AC, EMG, baseline drift, high-frequency, and low-frequency filters \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1107\" data-end=\"1133\"\u003e\n\n\u003cp data-start=\"1109\" data-end=\"1133\"\u003e A\/D resolution: 18-bit \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1134\" data-end=\"1177\"\u003e\n\n\u003cp data-start=\"1136\" data-end=\"1177\"\u003e Sampling rate: 8000 samples\/sec\/channel \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"1179\" data-end=\"1182\"\u003e\n\n\u003ch2 data-start=\"1184\" data-end=\"1207\"\u003e Recording \u0026amp; Printing \u003c\/h2\u003e\n\n\u003cul data-start=\"1209\" data-end=\"1898\"\u003e\n\n\u003cli data-start=\"1209\" data-end=\"1258\"\u003e\n\n\u003cp data-start=\"1211\" data-end=\"1258\"\u003e Recording speed: 5, 10, 12.5, 25, 50 mm\/s ±3% \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1259\" data-end=\"1341\"\u003e\n\n\u003cp data-start=\"1261\" data-end=\"1293\"\u003e Thermal print head resolution: \u003c\/p\u003e\n\n\u003cul data-start=\"1296\" data-end=\"1341\"\u003e\n\n\u003cli data-start=\"1296\" data-end=\"1319\"\u003e\n\n\u003cp data-start=\"1298\" data-end=\"1319\"\u003e Vertical: 8 dots\/mm \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1322\" data-end=\"1341\"\u003e\n\n\u003cp data-start=\"1324\" data-end=\"1341\"\u003e Time axis: 1 ms \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1342\" data-end=\"1472\"\u003e\n\n\u003cp data-start=\"1344\" data-end=\"1365\"\u003e Recording channels: \u003c\/p\u003e\n\n\u003cul data-start=\"1368\" data-end=\"1472\"\u003e\n\n\u003cli data-start=\"1368\" data-end=\"1381\"\u003e\n\n\u003cp data-start=\"1370\" data-end=\"1381\"\u003e 3-channel \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1384\" data-end=\"1405\"\u003e\n\n\u003cp data-start=\"1386\" data-end=\"1405\"\u003e 3+1 (rhythm lead) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1408\" data-end=\"1429\"\u003e\n\n\u003cp data-start=\"1410\" data-end=\"1429\"\u003e 3+2 (rhythm lead) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1432\" data-end=\"1445\"\u003e\n\n\u003cp data-start=\"1434\" data-end=\"1445\"\u003e 6-channel \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1448\" data-end=\"1455\"\u003e\n\n\u003cp data-start=\"1450\" data-end=\"1455\"\u003e 6+1 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1458\" data-end=\"1472\"\u003e\n\n\u003cp data-start=\"1460\" data-end=\"1472\"\u003e 12-channel \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1473\" data-end=\"1521\"\u003e\n\n\u003cp data-start=\"1475\" data-end=\"1521\"\u003e Recording paper: 210 mm wide roll paper (A4) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1522\" data-end=\"1642\"\u003e\n\n\u003cp data-start=\"1524\" data-end=\"1642\"\u003e Recording method: Built-in thermal array recorder, supporting automatic, manual, measurement, and analysis recording \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1643\" data-end=\"1898\"\u003e\n\n\u003cp data-start=\"1645\" data-end=\"1745\"\u003e Capable of printing ECG waveforms, measurement values, and analysis\/diagnostic reports, including: \u003c\/p\u003e\n\n\u003cul data-start=\"1748\" data-end=\"1898\"\u003e\n\n\u003cli data-start=\"1748\" data-end=\"1774\"\u003e\n\n\u003cp data-start=\"1750\" data-end=\"1774\"\u003e Rhythm analysis report \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1777\" data-end=\"1807\"\u003e\n\n\u003cp data-start=\"1779\" data-end=\"1807\"\u003e Arrhythmia analysis report \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1810\" data-end=\"1853\"\u003e\n\n\u003cp data-start=\"1812\" data-end=\"1853\"\u003e ST segment quantitative analysis report \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1856\" data-end=\"1898\"\u003e\n\n\u003cp data-start=\"1858\" data-end=\"1898\"\u003e RR interval histogram and trend graph \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"1900\" data-end=\"1903\"\u003e\n\n\u003ch2 data-start=\"1905\" data-end=\"1936\"\u003e Advanced Recording Functions \u003c\/h2\u003e\n\n\u003cul data-start=\"1938\" data-end=\"2276\"\u003e\n\n\u003cli data-start=\"1938\" data-end=\"2038\"\u003e\n\n\u003cp data-start=\"1940\" data-end=\"2038\"\u003e Record review: Playback of 24-second measured ECG waveforms or review of 10-second ECG waveforms \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2039\" data-end=\"2128\"\u003e\n\n\u003cp data-start=\"2041\" data-end=\"2128\"\u003e Post-exercise recording: Ability to record ECG waveforms after exercise or medication\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2129\" data-end=\"2276\"\u003e\n\n \u003cp data-start=\"2131\" data-end=\"2276\"\u003eAutomatic arrhythmia extended recording: During analysis, when arrhythmia is detected, the system automatically prints an arrhythmia ECG report \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"2278\" data-end=\"2281\"\u003e\n\n\u003ch2 data-start=\"2283\" data-end=\"2306\"\u003e Storage \u0026amp; Interfaces \u003c\/h2\u003e\n\n\u003cul data-start=\"2308\" data-end=\"2529\"\u003e\n\n\u003cli data-start=\"2308\" data-end=\"2380\"\u003e\n\n\u003cp data-start=\"2310\" data-end=\"2380\"\u003e Storage capacity: Main unit can store more than 300 sets of ECG data \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2381\" data-end=\"2443\"\u003e\n\n\u003cp data-start=\"2383\" data-end=\"2443\"\u003e Output display: Supports connection to a secondary display \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2444\" data-end=\"2529\"\u003e\n\n\u003cp data-start=\"2446\" data-end=\"2529\"\u003e Serial interface: Built-in RS-232C serial interface module (optional PC software) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"2531\" data-end=\"2534\"\u003e\n\n\u003ch2 data-start=\"2536\" data-end=\"2557\"\u003e Optional Functions \u003c\/h2\u003e\n\n\u003cul data-start=\"2559\" data-end=\"2672\"\u003e\n\n\u003cli data-start=\"2559\" data-end=\"2641\"\u003e\n\n\u003cp data-start=\"2561\" data-end=\"2641\"\u003e Optional PC card support, capable of storing several thousand ECG data records \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2642\" data-end=\"2672\"\u003e\n\n\u003cp data-start=\"2644\" data-end=\"2672\"\u003e Supports software upgrades\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Revive Med Lab","offers":[{"title":"Default Title","offer_id":45630069506209,"sku":null,"price":20000.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/9620\/1633\/files\/20260327160936_804_153.jpg?v=1774601621","url":"https:\/\/www.revivemedlab.com\/products\/twelve-channel-automatic-analysis-electrocardiograph-fx-7402","provider":"Reco Link","version":"1.0","type":"link"}