{"product_id":"arm-cylinder-electronic-blood-pressure-monitor-hbp-9020","title":"Arm Cylinder Electronic Blood Pressure Monitor HBP-9020","description":"\u003ch4 data-start=\"170\" data-end=\"194\"\u003eMedical Device Name\u003c\/h4\u003e\n\u003cp data-start=\"195\" data-end=\"226\"\u003e\u003cstrong data-start=\"195\" data-end=\"226\"\u003eNon-Mydriatic Fundus Camera\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"228\" data-end=\"231\"\u003e\n\u003ch4 data-start=\"233\" data-end=\"253\"\u003eBasic Information\u003c\/h4\u003e\n\u003cp data-start=\"255\" data-end=\"432\"\u003e\u003cstrong data-start=\"255\" data-end=\"265\"\u003eBrand:\u003c\/strong\u003e Omron\u003cbr data-start=\"280\" data-end=\"283\"\u003e\u003cstrong data-start=\"283\" data-end=\"293\"\u003eModel:\u003c\/strong\u003e HBP-9020\u003cbr data-start=\"303\" data-end=\"306\"\u003e\u003cstrong data-start=\"306\" data-end=\"330\"\u003eYear of Manufacture:\u003c\/strong\u003e 2017\u003cbr data-start=\"335\" data-end=\"338\"\u003e\u003cstrong data-start=\"338\" data-end=\"355\"\u003eManufacturer:\u003c\/strong\u003e Omron (Dalian) Co., Ltd.\u003cbr data-start=\"374\" data-end=\"377\"\u003e\u003cstrong data-start=\"377\" data-end=\"391\"\u003eCondition:\u003c\/strong\u003e Pre-Owned\u003cbr data-start=\"401\" data-end=\"404\"\u003e\u003cstrong data-start=\"404\" data-end=\"421\"\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/p\u003e\n\u003chr data-start=\"434\" data-end=\"437\"\u003e\n\u003ch4 data-start=\"439\" data-end=\"458\"\u003eProduct Overview\u003c\/h4\u003e\n\u003cp data-end=\"368\" data-start=\"97\"\u003eThe HBP-9020 Blood Pressure Monitor is a professional medical device designed for accurate, stable, and efficient blood pressure measurement in clinical environments. Utilizing advanced oscillometric technology, it ensures reliable performance and consistent results.\u003c\/p\u003e\n\u003cp data-end=\"527\" data-start=\"370\"\u003eEngineered for hospitals, clinics, and healthcare institutions, the system supports daily medical workflows with high precision, durability, and ease of use.\u003c\/p\u003e\n\u003chr data-start=\"1077\" data-end=\"1080\"\u003e\n\u003ch4 data-start=\"1082\" data-end=\"1101\"\u003eProduct Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-end=\"629\" data-start=\"560\"\u003eAdvanced oscillometric measurement technology for accurate readings\u003c\/li\u003e\n\u003cli data-end=\"696\" data-start=\"632\"\u003eWide measurement range suitable for diverse patient conditions\u003c\/li\u003e\n\u003cli data-end=\"752\" data-start=\"699\"\u003eHigh precision with clinically reliable performance\u003c\/li\u003e\n\u003cli data-end=\"801\" data-start=\"755\"\u003eUser-friendly design for efficient operation\u003c\/li\u003e\n\u003cli data-end=\"845\" data-start=\"804\"\u003eRS-232 interface for system integration\u003c\/li\u003e\n\u003cli data-end=\"896\" data-start=\"848\"\u003eDurable construction for long-term medical use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1663\" data-end=\"1666\"\u003e\n\u003ch4 data-start=\"1668\" data-end=\"1708\"\u003eHBP-9020 Blood Pressure Monitor\u003c\/h4\u003e\n\u003ch3 data-end=\"976\" data-start=\"942\" data-section-id=\"r3otuq\"\u003e\u003cstrong data-end=\"976\" data-start=\"946\"\u003eMeasurement Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1196\" data-start=\"977\"\u003e\n\u003cli data-end=\"1025\" data-start=\"977\" data-section-id=\"njo1ut\"\u003e\n\u003cp data-end=\"1025\" data-start=\"979\"\u003e\u003cstrong data-end=\"1002\" data-start=\"979\"\u003eMeasurement Method:\u003c\/strong\u003e Oscillometric Method\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1077\" data-start=\"1026\" data-section-id=\"s7x7eb\"\u003e\n\u003cp data-end=\"1077\" data-start=\"1028\"\u003e\u003cstrong data-end=\"1047\" data-start=\"1028\"\u003ePressure Range:\u003c\/strong\u003e 0 ~ 299 mmHg (0 ~ 39.9 kPa)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1122\" data-start=\"1078\" data-section-id=\"1bp3yhj\"\u003e\n\u003cp data-end=\"1122\" data-start=\"1080\"\u003e\u003cstrong data-end=\"1101\" data-start=\"1080\"\u003ePulse Rate Range:\u003c\/strong\u003e 40 ~ 180 beats\/min\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1168\" data-start=\"1123\" data-section-id=\"1lmx2ef\"\u003e\n\u003cp data-end=\"1168\" data-start=\"1125\"\u003e\u003cstrong data-end=\"1147\" data-start=\"1125\"\u003ePressure Accuracy:\u003c\/strong\u003e ±3 mmHg (±0.4 kPa)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1196\" data-start=\"1169\" data-section-id=\"18a236e\"\u003e\n\u003cp data-end=\"1196\" data-start=\"1171\"\u003e\u003cstrong data-end=\"1190\" data-start=\"1171\"\u003ePulse Accuracy:\u003c\/strong\u003e ±2%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1201\" data-start=\"1198\"\u003e\n\u003ch3 data-end=\"1231\" data-start=\"1203\" data-section-id=\"1wc0d3u\"\u003e\u003cstrong data-end=\"1231\" data-start=\"1207\"\u003eCuff \u0026amp; Patient Range\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1272\" data-start=\"1232\"\u003e\n\u003cli data-end=\"1272\" data-start=\"1232\" data-section-id=\"111zm3x\"\u003e\n\u003cp data-end=\"1272\" data-start=\"1234\"\u003e\u003cstrong data-end=\"1256\" data-start=\"1234\"\u003eArm Circumference:\u003c\/strong\u003e 17 cm ~ 42 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1277\" data-start=\"1274\"\u003e\n\u003ch3 data-end=\"1305\" data-start=\"1279\" data-section-id=\"1umuqut\"\u003e\u003cstrong data-end=\"1305\" data-start=\"1283\"\u003ePower Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1345\" data-start=\"1306\"\u003e\n\u003cli data-end=\"1345\" data-start=\"1306\" data-section-id=\"xv90yw\"\u003e\n\u003cp data-end=\"1345\" data-start=\"1308\"\u003e\u003cstrong data-end=\"1325\" data-start=\"1308\"\u003ePower Supply:\u003c\/strong\u003e AC 220V, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1350\" data-start=\"1347\"\u003e\n\u003ch3 data-end=\"1384\" data-start=\"1352\" data-section-id=\"o3p6pq\"\u003e\u003cstrong data-end=\"1384\" data-start=\"1356\"\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1410\" data-start=\"1386\"\u003e\u003cstrong data-end=\"1410\" data-start=\"1386\"\u003eOperating Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1470\" data-start=\"1411\"\u003e\n\u003cli data-end=\"1440\" data-start=\"1411\" data-section-id=\"z07o1d\"\u003e\n\u003cp data-end=\"1440\" data-start=\"1413\"\u003eTemperature: +5°C ~ +40°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1470\" data-start=\"1441\" data-section-id=\"1bu05rw\"\u003e\n\u003cp data-end=\"1470\" data-start=\"1443\"\u003eHumidity: 15% RH ~ 85% RH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1506\" data-start=\"1472\"\u003e\u003cstrong data-end=\"1506\" data-start=\"1472\"\u003eStorage \u0026amp; Transport Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1567\" data-start=\"1507\"\u003e\n\u003cli data-end=\"1537\" data-start=\"1507\" data-section-id=\"xahj1e\"\u003e\n\u003cp data-end=\"1537\" data-start=\"1509\"\u003eTemperature: -20°C ~ +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1567\" data-start=\"1538\" data-section-id=\"qvjbco\"\u003e\n\u003cp data-end=\"1567\" data-start=\"1540\"\u003eHumidity: 10% RH ~ 95% RH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1593\" data-start=\"1569\"\u003e\u003cstrong data-end=\"1593\" data-start=\"1569\"\u003eAtmospheric Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1669\" data-start=\"1594\"\u003e\n\u003cli data-end=\"1627\" data-start=\"1594\" data-section-id=\"hnk1j5\"\u003e\n\u003cp data-end=\"1627\" data-start=\"1596\"\u003eOperating: 700 hPa ~ 1060 hPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1669\" data-start=\"1628\" data-section-id=\"180grfv\"\u003e\n\u003cp data-end=\"1669\" data-start=\"1630\"\u003eStorage\/Transport: 500 hPa ~ 1060 hPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1674\" data-start=\"1671\"\u003e\n\u003ch3 data-end=\"1707\" data-start=\"1676\" data-section-id=\"jrwbel\"\u003e\u003cstrong data-end=\"1707\" data-start=\"1680\"\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1821\" data-start=\"1708\"\u003e\n\u003cli data-end=\"1738\" data-start=\"1708\" data-section-id=\"79bdzu\"\u003e\n\u003cp data-end=\"1738\" data-start=\"1710\"\u003e\u003cstrong data-end=\"1721\" data-start=\"1710\"\u003eWeight:\u003c\/strong\u003e Approx. 5.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1821\" data-start=\"1739\" data-section-id=\"17sk5nv\"\u003e\n\u003cp data-end=\"1821\" data-start=\"1741\"\u003e\u003cstrong data-end=\"1756\" data-start=\"1741\"\u003eDimensions:\u003c\/strong\u003e 460 mm (W) × 270 mm (H) × 370 mm (D) \u003cem data-end=\"1819\" data-start=\"1794\"\u003e(excluding arm support)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1826\" data-start=\"1823\"\u003e\n\u003ch3 data-end=\"1845\" data-start=\"1828\" data-section-id=\"nzy1mr\"\u003e\u003cstrong data-end=\"1845\" data-start=\"1832\"\u003eInterface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1873\" data-start=\"1846\"\u003e\n\u003cli data-end=\"1873\" data-start=\"1846\" data-section-id=\"ld6m5n\"\u003e\n\u003cp data-end=\"1873\" data-start=\"1848\"\u003e\u003cstrong data-end=\"1864\" data-start=\"1848\"\u003eOutput Port:\u003c\/strong\u003e RS-232\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2218\" data-end=\"2221\"\u003e\n\u003ch4 data-start=\"2223\" data-end=\"2255\"\u003eHBP-9020 Key Characteristics\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-end=\"2008\" data-start=\"1918\"\u003e\n\u003cstrong data-end=\"1948\" data-start=\"1918\"\u003eReliable Clinical Accuracy\u003c\/strong\u003e\u003cbr data-end=\"1951\" data-start=\"1948\"\u003eEnsures consistent and dependable measurement results\u003c\/li\u003e\n\u003cli data-end=\"2088\" data-start=\"2010\" data-section-id=\"1fumfwv\"\u003e\n\u003cp data-end=\"2088\" data-start=\"2012\"\u003e\u003cstrong data-end=\"2042\" data-start=\"2012\"\u003eWide Patient Compatibility\u003c\/strong\u003e\u003cbr data-end=\"2045\" data-start=\"2042\"\u003eSuitable for a broad range of arm sizes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2179\" data-start=\"2090\" data-section-id=\"5bnwpj\"\u003e\n\u003cp data-end=\"2179\" data-start=\"2092\"\u003e\u003cstrong data-end=\"2125\" data-start=\"2092\"\u003eSystem Integration Capability\u003c\/strong\u003e\u003cbr data-end=\"2128\" data-start=\"2125\"\u003eSupports data transmission via RS-232 interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2290\" data-start=\"2181\" data-section-id=\"xapwq\"\u003e\n\u003cp data-end=\"2216\" data-start=\"2183\"\u003e\u003cstrong data-end=\"2214\" data-start=\"2183\"\u003eMedical-Grade Safety Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul data-end=\"2290\" data-start=\"2219\"\u003e\n\u003cli data-end=\"2262\" data-start=\"2219\" data-section-id=\"1horb1k\"\u003e\n\u003cp data-end=\"2262\" data-start=\"2221\"\u003eClass II Equipment, Type B Applied Part\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2290\" data-start=\"2265\" data-section-id=\"1i328dz\"\u003e\n\u003cp data-end=\"2290\" data-start=\"2267\"\u003eEMC: Group 1, Class B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2290\" data-start=\"2267\"\u003e\n\u003cstrong\u003eOperational Safety Notice\u003c\/strong\u003e\u003cbr data-end=\"2326\" data-start=\"2323\"\u003eNot suitable for use in environments with flammable anesthetic gases mixed with air, oxygen, or nitrous oxide、\u003c\/li\u003e\n\u003cli data-end=\"2290\" data-start=\"2267\"\u003e\n\u003cstrong data-end=\"2475\" data-start=\"2443\"\u003eStable \u0026amp; Durable Performance\u003c\/strong\u003e\u003cbr data-end=\"2478\" data-start=\"2475\"\u003eDesigned for continuous operation in professional healthcare environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Revive Med Lab","offers":[{"title":"Default Title","offer_id":45839091892385,"sku":null,"price":10000.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/9620\/1633\/files\/20260327160708_790_153_b0d08625-a121-42f4-9bc7-6721fa9c6214.jpg?v=1774600504","url":"https:\/\/www.revivemedlab.com\/zh\/products\/arm-cylinder-electronic-blood-pressure-monitor-hbp-9020","provider":"Reco Link","version":"1.0","type":"link"}