{"product_id":"twelve-channel-automatic-analysis-electrocardiograph-fx-7402","title":"MetriScan Finger Bone Densitometer","description":"\u003cdiv\u003e\n\u003cstrong\u003eMedical Device Name\u003c\/strong\u003e: MetriScan Finger Bone Densitometer\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: MetriScan\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eCondition\u003c\/strong\u003e: \u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eFull Unit in Good Working Condition\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eInventory Status\u003c\/strong\u003e: In stock\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIt is used for rapid and low-dose finger bone mineral density detection, assisting in the diagnosis of osteoporosis and assessment of fracture risk.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCore Principle \u0026amp; Detection Site\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eTechnical Principle\u003c\/strong\u003e: Adopts Radiographic Absorptiometry (RA) combined with Storage Phosphor Technology (SPT) to measure bone mineral density via X-ray digital image absorption method.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eDetection Site\u003c\/strong\u003e: Middle phalanges of the 2nd, 3rd and 4th fingers of the non-dominant hand.\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cstrong\u003eCore Parameters\u003c\/strong\u003e: Automatically calculates \u003cstrong\u003eT-score\u003c\/strong\u003e (compared with healthy young females for osteoporosis judgment) and \u003cstrong\u003eZ-score\u003c\/strong\u003e (compared with population of the same age, gender and race to analyze the causes of bone loss).\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eKey Technical Parameters\u003c\/h2\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Specification\u003c\/strong\u003e: Tabletop type; Dimension: 40.6cm×40.6cm×40.6cm; Weight: 18.8kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eX-ray Parameters\u003c\/strong\u003e: Voltage 60KV, Current 0.333mA, Exposure time: 0.3 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiation Dose\u003c\/strong\u003e: Single effective dose 0.012μSv, approximately 1\/10000 of a standard chest X-ray, safe and controllable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Efficiency\u003c\/strong\u003e: Exposure time＜1 second, test result available in 40 seconds, the whole process (including report printing) ≤ 2 minutes..\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"448\" data-end=\"451\"\u003e\n\u003ch4 data-start=\"453\" data-end=\"477\"\u003eDisplay \u0026amp; Acquisition\u003c\/h4\u003e\n\u003cul data-start=\"479\" data-end=\"606\"\u003e\n\u003cli data-start=\"479\" data-end=\"524\"\u003e\n\u003cp data-start=\"481\" data-end=\"524\"\u003e5.6-inch LCD touch display with backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"525\" data-end=\"606\"\u003e\n\u003cp data-start=\"527\" data-end=\"606\"\u003eTwelve-lead synchronous acquisition and recording, standard 12-lead recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"608\" data-end=\"611\"\u003e\n\u003ch4 data-start=\"613\" data-end=\"638\"\u003eElectrical Performance\u003c\/h4\u003e\n\u003cul data-start=\"640\" data-end=\"998\"\u003e\n\u003cli data-start=\"640\" data-end=\"675\"\u003e\n\u003cp data-start=\"642\" data-end=\"675\"\u003eInput impedance: \u0026gt;50 MΩ (10 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"676\" data-end=\"709\"\u003e\n\u003cp data-start=\"678\" data-end=\"709\"\u003eInput circuit current: \u0026lt;50 nA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"710\" data-end=\"753\"\u003e\n\u003cp data-start=\"712\" data-end=\"753\"\u003eFrequency response: 0.05–150 Hz (-3 dB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"754\" data-end=\"805\"\u003e\n\u003cp data-start=\"756\" data-end=\"805\"\u003eGain: 1\/4, 1\/2, 1, 2 cm\/mV, manual or automatic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"806\" data-end=\"853\"\u003e\n\u003cp data-start=\"808\" data-end=\"853\"\u003eCommon mode rejection ratio (CMRR): \u0026gt;103 dB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"854\" data-end=\"892\"\u003e\n\u003cp data-start=\"856\" data-end=\"892\"\u003eAnti-polarization voltage: \u0026gt;550 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"893\" data-end=\"956\"\u003e\n\u003cp data-start=\"895\" data-end=\"956\"\u003eDefibrillation protection with anti-defibrillation function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"998\"\u003e\n\u003cp data-start=\"959\" data-end=\"998\"\u003eTime constant: 3.2 seconds (0 ~ +20%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1000\" data-end=\"1003\"\u003e\n\u003ch4 data-start=\"1005\" data-end=\"1025\"\u003eSignal Processing\u003c\/h4\u003e\n\u003cul data-start=\"1027\" data-end=\"1177\"\u003e\n\u003cli data-start=\"1027\" data-end=\"1106\"\u003e\n\u003cp data-start=\"1029\" data-end=\"1106\"\u003eFilters: AC, EMG, baseline drift, high-frequency, and low-frequency filters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1107\" data-end=\"1133\"\u003e\n\u003cp data-start=\"1109\" data-end=\"1133\"\u003eA\/D resolution: 18-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1134\" data-end=\"1177\"\u003e\n\u003cp data-start=\"1136\" data-end=\"1177\"\u003eSampling rate: 8000 samples\/sec\/channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1179\" data-end=\"1182\"\u003e\n\u003ch4 data-start=\"1184\" data-end=\"1207\"\u003eRecording \u0026amp; Printing\u003c\/h4\u003e\n\u003cul data-start=\"1209\" data-end=\"1898\"\u003e\n\u003cli data-start=\"1209\" data-end=\"1258\"\u003e\n\u003cp data-start=\"1211\" data-end=\"1258\"\u003eRecording speed: 5, 10, 12.5, 25, 50 mm\/s ±3%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1259\" data-end=\"1341\"\u003e\n\u003cp data-start=\"1261\" data-end=\"1293\"\u003eThermal print head resolution:\u003c\/p\u003e\n\u003cul data-start=\"1296\" data-end=\"1341\"\u003e\n\u003cli data-start=\"1296\" data-end=\"1319\"\u003e\n\u003cp data-start=\"1298\" data-end=\"1319\"\u003eVertical: 8 dots\/mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1322\" data-end=\"1341\"\u003e\n\u003cp data-start=\"1324\" data-end=\"1341\"\u003eTime axis: 1 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1342\" data-end=\"1472\"\u003e\n\u003cp data-start=\"1344\" data-end=\"1365\"\u003eRecording channels:\u003c\/p\u003e\n\u003cul data-start=\"1368\" data-end=\"1472\"\u003e\n\u003cli data-start=\"1368\" data-end=\"1381\"\u003e\n\u003cp data-start=\"1370\" data-end=\"1381\"\u003e3-channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1384\" data-end=\"1405\"\u003e\n\u003cp data-start=\"1386\" data-end=\"1405\"\u003e3+1 (rhythm lead)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1408\" data-end=\"1429\"\u003e\n\u003cp data-start=\"1410\" data-end=\"1429\"\u003e3+2 (rhythm lead)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1432\" data-end=\"1445\"\u003e\n\u003cp data-start=\"1434\" data-end=\"1445\"\u003e6-channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1455\"\u003e\n\u003cp data-start=\"1450\" data-end=\"1455\"\u003e6+1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1458\" data-end=\"1472\"\u003e\n\u003cp data-start=\"1460\" data-end=\"1472\"\u003e12-channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1473\" data-end=\"1521\"\u003e\n\u003cp data-start=\"1475\" data-end=\"1521\"\u003eRecording paper: 210 mm wide roll paper (A4)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1522\" data-end=\"1642\"\u003e\n\u003cp data-start=\"1524\" data-end=\"1642\"\u003eRecording method: Built-in thermal array recorder, supporting automatic, manual, measurement, and analysis recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1643\" data-end=\"1898\"\u003e\n\u003cp data-start=\"1645\" data-end=\"1745\"\u003eCapable of printing ECG waveforms, measurement values, and analysis\/diagnostic reports, including:\u003c\/p\u003e\n\u003cul data-start=\"1748\" data-end=\"1898\"\u003e\n\u003cli data-start=\"1748\" data-end=\"1774\"\u003e\n\u003cp data-start=\"1750\" data-end=\"1774\"\u003eRhythm analysis report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1777\" data-end=\"1807\"\u003e\n\u003cp data-start=\"1779\" data-end=\"1807\"\u003eArrhythmia analysis report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1810\" data-end=\"1853\"\u003e\n\u003cp data-start=\"1812\" data-end=\"1853\"\u003eST segment quantitative analysis report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1856\" data-end=\"1898\"\u003e\n\u003cp data-start=\"1858\" data-end=\"1898\"\u003eR-R interval histogram and trend graph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1900\" data-end=\"1903\"\u003e\n\u003ch4 data-start=\"1905\" data-end=\"1936\"\u003eAdvanced Recording Functions\u003c\/h4\u003e\n\u003cul data-start=\"1938\" data-end=\"2276\"\u003e\n\u003cli data-start=\"1938\" data-end=\"2038\"\u003e\n\u003cp data-start=\"1940\" data-end=\"2038\"\u003eRecord review: Playback of 24-second measured ECG waveforms or review of 10-second ECG waveforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2039\" data-end=\"2128\"\u003e\n\u003cp data-start=\"2041\" data-end=\"2128\"\u003ePost-exercise recording: Ability to record ECG waveforms after exercise or medication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2129\" data-end=\"2276\"\u003e\n\u003cp data-start=\"2131\" data-end=\"2276\"\u003eAutomatic arrhythmia extended recording: During analysis, when arrhythmia is detected, the system automatically prints an arrhythmia ECG report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2278\" data-end=\"2281\"\u003e\n\u003ch4 data-start=\"2283\" data-end=\"2306\"\u003eStorage \u0026amp; Interfaces\u003c\/h4\u003e\n\u003cul data-start=\"2308\" data-end=\"2529\"\u003e\n\u003cli data-start=\"2308\" data-end=\"2380\"\u003e\n\u003cp data-start=\"2310\" data-end=\"2380\"\u003eStorage capacity: Main unit can store more than 300 sets of ECG data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2381\" data-end=\"2443\"\u003e\n\u003cp data-start=\"2383\" data-end=\"2443\"\u003eOutput display: Supports connection to a secondary display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2444\" data-end=\"2529\"\u003e\n\u003cp data-start=\"2446\" data-end=\"2529\"\u003eSerial interface: Built-in RS-232C serial interface module (optional PC software)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2531\" data-end=\"2534\"\u003e\n\u003ch4 data-start=\"2536\" data-end=\"2557\"\u003eOptional Functions\u003c\/h4\u003e\n\u003cul data-start=\"2559\" data-end=\"2672\"\u003e\n\u003cli data-start=\"2559\" data-end=\"2641\"\u003e\n\u003cp data-start=\"2561\" data-end=\"2641\"\u003eOptional PC card support, capable of storing several thousand ECG data records\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2642\" data-end=\"2672\"\u003e\n\u003cp data-start=\"2644\" data-end=\"2672\"\u003eSupports software upgrades\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Revive Med Lab","offers":[{"title":"Default Title","offer_id":45630069506209,"sku":null,"price":20000.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/9620\/1633\/files\/20260327160936_804_153.jpg?v=1774601621","url":"https:\/\/www.revivemedlab.com\/zh\/products\/twelve-channel-automatic-analysis-electrocardiograph-fx-7402","provider":"Reco Link","version":"1.0","type":"link"}