{"product_id":"twelve-channel-automatic-analysis-electrocardiograph-fx-8322","title":"Twelve-channel Automatic Analysis Electrocardiograph FX-8322","description":"\u003ch4 data-start=\"151\" data-end=\"175\"\u003eMedical Device Name\u003c\/h4\u003e\n\u003cp data-start=\"176\" data-end=\"228\"\u003e\u003cstrong data-start=\"176\" data-end=\"228\"\u003e12-Channel Automatic Analysis Electrocardiograph\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"230\" data-end=\"233\"\u003e\n\u003ch4 data-start=\"235\" data-end=\"255\"\u003eBasic Information\u003c\/h4\u003e\n\u003cp data-start=\"257\" data-end=\"441\"\u003e\u003cstrong data-start=\"257\" data-end=\"267\"\u003eBrand:\u003c\/strong\u003e Fukuda Electronics\u003cbr data-start=\"286\" data-end=\"289\"\u003e\u003cstrong data-start=\"289\" data-end=\"299\"\u003eModel:\u003c\/strong\u003e FX-8322\u003cbr data-start=\"307\" data-end=\"310\"\u003e\u003cstrong data-start=\"310\" data-end=\"327\"\u003eManufacturer:\u003c\/strong\u003e Beijing Fukuda Electronics Medical Instrument Co., Ltd.\u003cbr data-start=\"383\" data-end=\"386\"\u003e\u003cstrong data-start=\"386\" data-end=\"400\"\u003eCondition:\u003c\/strong\u003e Pre-Owned\u003cbr data-start=\"410\" data-end=\"413\"\u003e\u003cstrong data-start=\"413\" data-end=\"430\"\u003eAvailability:\u003c\/strong\u003e In Stock\u003c\/p\u003e\n\u003chr data-start=\"443\" data-end=\"446\"\u003e\n\u003ch4 data-start=\"448\" data-end=\"481\"\u003eLead Acquisition \u0026amp; Performance\u003c\/h4\u003e\n\u003cul data-start=\"483\" data-end=\"699\"\u003e\n\u003cli data-start=\"483\" data-end=\"565\"\u003e\n\u003cp data-start=\"485\" data-end=\"565\"\u003eLeads: Standard 12 leads, twelve-channel synchronous acquisition and recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"566\" data-end=\"611\"\u003e\n\u003cp data-start=\"568\" data-end=\"611\"\u003ePolarization withstand voltage: ≥ ±550 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"612\" data-end=\"660\"\u003e\n\u003cp data-start=\"614\" data-end=\"660\"\u003eCommon mode rejection ratio (CMRR): ≥ 103 dB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"661\" data-end=\"699\"\u003e\n\u003cp data-start=\"663\" data-end=\"699\"\u003eSampling rate: 8000 samples\/second\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"701\" data-end=\"704\"\u003e\n\u003ch4 data-start=\"706\" data-end=\"728\"\u003eDisplay \u0026amp; Interface\u003c\/h4\u003e\n\u003cul data-start=\"730\" data-end=\"1053\"\u003e\n\u003cli data-start=\"730\" data-end=\"842\"\u003e\n\u003cp data-start=\"732\" data-end=\"751\"\u003eBuilt-in display:\u003c\/p\u003e\n\u003cul data-start=\"754\" data-end=\"842\"\u003e\n\u003cli data-start=\"754\" data-end=\"793\"\u003e\n\u003cp data-start=\"756\" data-end=\"793\"\u003eColor LCD touch screen ≥ 6.5 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"796\" data-end=\"821\"\u003e\n\u003cp data-start=\"798\" data-end=\"821\"\u003eResolution: 640 × 480\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"824\" data-end=\"842\"\u003e\n\u003cp data-start=\"826\" data-end=\"842\"\u003eWith backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"843\" data-end=\"1053\"\u003e\n\u003cp data-start=\"845\" data-end=\"872\"\u003eDisplay content includes:\u003c\/p\u003e\n\u003cul data-start=\"875\" data-end=\"1053\"\u003e\n\u003cli data-start=\"875\" data-end=\"912\"\u003e\n\u003cp data-start=\"877\" data-end=\"912\"\u003e3, 6, or 12-channel ECG waveforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"915\" data-end=\"929\"\u003e\n\u003cp data-start=\"917\" data-end=\"929\"\u003eHeart rate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"932\" data-end=\"945\"\u003e\n\u003cp data-start=\"934\" data-end=\"945\"\u003eID number\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"948\" data-end=\"958\"\u003e\n\u003cp data-start=\"950\" data-end=\"958\"\u003eGender\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"961\" data-end=\"968\"\u003e\n\u003cp data-start=\"963\" data-end=\"968\"\u003eAge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"971\" data-end=\"991\"\u003e\n\u003cp data-start=\"973\" data-end=\"991\"\u003eOperating status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"994\" data-end=\"1012\"\u003e\n\u003cp data-start=\"996\" data-end=\"1012\"\u003eOperation menu\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1015\" data-end=\"1053\"\u003e\n\u003cp data-start=\"1017\" data-end=\"1053\"\u003eElectrode disconnection indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1055\" data-end=\"1058\"\u003e\n\u003ch4 data-start=\"1060\" data-end=\"1079\"\u003eSystem Functions\u003c\/h4\u003e\n\u003cul data-start=\"1081\" data-end=\"1294\"\u003e\n\u003cli data-start=\"1081\" data-end=\"1148\"\u003e\n\u003cp data-start=\"1083\" data-end=\"1148\"\u003eSelf-diagnosis function with device self-check and fault prompt\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1149\" data-end=\"1294\"\u003e\n\u003cp data-start=\"1151\" data-end=\"1171\"\u003eExamination modes:\u003c\/p\u003e\n\u003cul data-start=\"1174\" data-end=\"1294\"\u003e\n\u003cli data-start=\"1174\" data-end=\"1206\"\u003e\n\u003cp data-start=\"1176\" data-end=\"1206\"\u003eStandard 12-lead examination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1209\" data-end=\"1235\"\u003e\n\u003cp data-start=\"1211\" data-end=\"1235\"\u003eArrhythmia examination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1238\" data-end=\"1266\"\u003e\n\u003cp data-start=\"1240\" data-end=\"1266\"\u003eR-R interval measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1269\" data-end=\"1294\"\u003e\n\u003cp data-start=\"1271\" data-end=\"1294\"\u003ePost-load examination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1296\" data-end=\"1299\"\u003e\n\u003ch4 data-start=\"1301\" data-end=\"1323\"\u003eRecording Functions\u003c\/h4\u003e\n\u003cul data-start=\"1325\" data-end=\"1630\"\u003e\n\u003cli data-start=\"1325\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1327\" data-end=\"1345\"\u003eRecording modes:\u003c\/p\u003e\n\u003cul data-start=\"1348\" data-end=\"1516\"\u003e\n\u003cli data-start=\"1348\" data-end=\"1371\"\u003e\n\u003cp data-start=\"1350\" data-end=\"1371\"\u003eAutomatic recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1374\" data-end=\"1394\"\u003e\n\u003cp data-start=\"1376\" data-end=\"1394\"\u003eManual recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1397\" data-end=\"1417\"\u003e\n\u003cp data-start=\"1399\" data-end=\"1417\"\u003eReview recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1420\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1422\" data-end=\"1442\"\u003eExtended recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1445\" data-end=\"1467\"\u003e\n\u003cp data-start=\"1447\" data-end=\"1467\"\u003eInterval recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1470\" data-end=\"1489\"\u003e\n\u003cp data-start=\"1472\" data-end=\"1489\"\u003eTimed recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1492\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1494\" data-end=\"1516\"\u003eCompressed recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1517\" data-end=\"1563\"\u003e\n\u003cp data-start=\"1519\" data-end=\"1563\"\u003eAbnormal waveform marking during recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1564\" data-end=\"1630\"\u003e\n\u003cp data-start=\"1566\" data-end=\"1630\"\u003eRecording phase supports time-continuous and synchronous modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1632\" data-end=\"1635\"\u003e\n\u003ch4 data-start=\"1637\" data-end=\"1657\"\u003eAnalysis \u0026amp; Review\u003c\/h4\u003e\n\u003cul data-start=\"1659\" data-end=\"2132\"\u003e\n\u003cli data-start=\"1659\" data-end=\"1828\"\u003e\n\u003cp data-start=\"1661\" data-end=\"1680\"\u003eAnalysis results:\u003c\/p\u003e\n\u003cul data-start=\"1683\" data-end=\"1828\"\u003e\n\u003cli data-start=\"1683\" data-end=\"1768\"\u003e\n\u003cp data-start=\"1685\" data-end=\"1768\"\u003eAnalysis result reports can be printed during both manual and automatic recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1771\" data-end=\"1828\"\u003e\n\u003cp data-start=\"1773\" data-end=\"1828\"\u003eOutput of analysis results can be enabled or disabled\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1829\" data-end=\"1920\"\u003e\n\u003cp data-start=\"1831\" data-end=\"1850\"\u003eReview recording:\u003c\/p\u003e\n\u003cul data-start=\"1853\" data-end=\"1920\"\u003e\n\u003cli data-start=\"1853\" data-end=\"1920\"\u003e\n\u003cp data-start=\"1855\" data-end=\"1920\"\u003eCapable of recording ECG waveforms from the previous 10 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1921\" data-end=\"2084\"\u003e\n\u003cp data-start=\"1923\" data-end=\"1965\"\u003eAutomatic arrhythmia extended recording:\u003c\/p\u003e\n\u003cul data-start=\"1968\" data-end=\"2084\"\u003e\n\u003cli data-start=\"1968\" data-end=\"2084\"\u003e\n\u003cp data-start=\"1970\" data-end=\"2084\"\u003eDuring analysis recording, when arrhythmia is detected, the system automatically prints an arrhythmia ECG report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2085\" data-end=\"2132\"\u003e\n\u003cp data-start=\"2087\" data-end=\"2132\"\u003eAnalysis result guidance function available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2134\" data-end=\"2137\"\u003e\n\u003ch4 data-start=\"2139\" data-end=\"2159\"\u003eRecording \u0026amp; Paper\u003c\/h4\u003e\n\u003cul data-start=\"2161\" data-end=\"2381\"\u003e\n\u003cli data-start=\"2161\" data-end=\"2305\"\u003e\n\u003cp data-start=\"2163\" data-end=\"2184\"\u003eRecording channels:\u003c\/p\u003e\n\u003cul data-start=\"2187\" data-end=\"2305\"\u003e\n\u003cli data-start=\"2187\" data-end=\"2195\"\u003e\n\u003cp data-start=\"2189\" data-end=\"2195\"\u003e3 CH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2198\" data-end=\"2224\"\u003e\n\u003cp data-start=\"2200\" data-end=\"2224\"\u003e3 CH + 1 (rhythm lead)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2227\" data-end=\"2253\"\u003e\n\u003cp data-start=\"2229\" data-end=\"2253\"\u003e3 CH + 2 (rhythm lead)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2256\" data-end=\"2264\"\u003e\n\u003cp data-start=\"2258\" data-end=\"2264\"\u003e6 CH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2267\" data-end=\"2293\"\u003e\n\u003cp data-start=\"2269\" data-end=\"2293\"\u003e6 CH + 1 (rhythm lead)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2296\" data-end=\"2305\"\u003e\n\u003cp data-start=\"2298\" data-end=\"2305\"\u003e12 CH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2306\" data-end=\"2381\"\u003e\n\u003cp data-start=\"2308\" data-end=\"2326\"\u003eRecording paper:\u003c\/p\u003e\n\u003cul data-start=\"2329\" data-end=\"2381\"\u003e\n\u003cli data-start=\"2329\" data-end=\"2381\"\u003e\n\u003cp data-start=\"2331\" data-end=\"2381\"\u003eBuilt-in 210 mm wide roll paper and folded paper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2383\" data-end=\"2386\"\u003e\n\u003ch4 data-start=\"2388\" data-end=\"2416\"\u003eStorage \u0026amp; Data Management\u003c\/h4\u003e\n\u003cul data-start=\"2418\" data-end=\"2619\"\u003e\n\u003cli data-start=\"2418\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2420\" data-end=\"2438\"\u003eInternal memory:\u003c\/p\u003e\n\u003cul data-start=\"2441\" data-end=\"2495\"\u003e\n\u003cli data-start=\"2441\" data-end=\"2495\"\u003e\n\u003cp data-start=\"2443\" data-end=\"2495\"\u003eMain unit can store more than 500 sets of ECG data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2496\" data-end=\"2619\"\u003e\n\u003cp data-start=\"2498\" data-end=\"2517\"\u003eExternal storage:\u003c\/p\u003e\n\u003cul data-start=\"2520\" data-end=\"2619\"\u003e\n\u003cli data-start=\"2520\" data-end=\"2550\"\u003e\n\u003cp data-start=\"2522\" data-end=\"2550\"\u003eSD card or USB flash drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2553\" data-end=\"2619\"\u003e\n\u003cp data-start=\"2555\" data-end=\"2619\"\u003eWith a 512 MB SD card, at least 15,000 ECG files can be stored\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2621\" data-end=\"2624\"\u003e\n\u003ch4 data-start=\"2626\" data-end=\"2657\"\u003eInput Devices \u0026amp; Connectivity\u003c\/h4\u003e\n\u003cul data-start=\"2659\" data-end=\"2858\"\u003e\n\u003cli data-start=\"2659\" data-end=\"2749\"\u003e\n\u003cp data-start=\"2661\" data-end=\"2677\"\u003eInput devices:\u003c\/p\u003e\n\u003cul data-start=\"2680\" data-end=\"2749\"\u003e\n\u003cli data-start=\"2680\" data-end=\"2706\"\u003e\n\u003cp data-start=\"2682\" data-end=\"2706\"\u003eBuilt-in full keyboard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2709\" data-end=\"2749\"\u003e\n\u003cp data-start=\"2711\" data-end=\"2749\"\u003eSupports external USB keyboard input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2750\" data-end=\"2858\"\u003e\n\u003cp data-start=\"2752\" data-end=\"2770\"\u003eInterface types:\u003c\/p\u003e\n\u003cul data-start=\"2773\" data-end=\"2858\"\u003e\n\u003cli data-start=\"2773\" data-end=\"2800\"\u003e\n\u003cp data-start=\"2775\" data-end=\"2800\"\u003eRS-232 serial ports × 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2803\" data-end=\"2820\"\u003e\n\u003cp data-start=\"2805\" data-end=\"2820\"\u003eUSB ports × 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2823\" data-end=\"2843\"\u003e\n\u003cp data-start=\"2825\" data-end=\"2843\"\u003eSD card slot × 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2846\" data-end=\"2858\"\u003e\n\u003cp data-start=\"2848\" data-end=\"2858\"\u003eLAN port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2860\" data-end=\"2863\"\u003e\n\u003ch4 data-start=\"2865\" data-end=\"2883\"\u003eNetwork \u0026amp; Power\u003c\/h4\u003e\n\u003cul data-start=\"2885\" data-end=\"3075\"\u003e\n\u003cli data-start=\"2885\" data-end=\"2963\"\u003e\n\u003cp data-start=\"2887\" data-end=\"2906\"\u003eNetwork function:\u003c\/p\u003e\n\u003cul data-start=\"2909\" data-end=\"2963\"\u003e\n\u003cli data-start=\"2909\" data-end=\"2963\"\u003e\n\u003cp data-start=\"2911\" data-end=\"2963\"\u003eBuilt-in LAN interface (optional wireless network)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2964\" data-end=\"3075\"\u003e\n\u003cp data-start=\"2966\" data-end=\"2987\"\u003ePower requirements:\u003c\/p\u003e\n\u003cul data-start=\"2990\" data-end=\"3075\"\u003e\n\u003cli data-start=\"2990\" data-end=\"3014\"\u003e\n\u003cp data-start=\"2992\" data-end=\"3014\"\u003eAC: 100–240 V, 50 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3017\" data-end=\"3075\"\u003e\n\u003cp data-start=\"3019\" data-end=\"3075\"\u003eDC: Built-in rechargeable lithium battery with charger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3077\" data-end=\"3080\"\u003e\n\u003ch4 data-start=\"3082\" data-end=\"3118\"\u003eBattery Performance \u0026amp; Accessories\u003c\/h4\u003e\n\u003cul data-start=\"3120\" data-end=\"3404\"\u003e\n\u003cli data-start=\"3120\" data-end=\"3249\"\u003e\n\u003cp data-start=\"3122\" data-end=\"3142\"\u003eDC operating time:\u003c\/p\u003e\n\u003cul data-start=\"3145\" data-end=\"3249\"\u003e\n\u003cli data-start=\"3145\" data-end=\"3184\"\u003e\n\u003cp data-start=\"3147\" data-end=\"3184\"\u003eContinuous operation for 90 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3187\" data-end=\"3249\"\u003e\n\u003cp data-start=\"3189\" data-end=\"3249\"\u003eBased on IEC 60601-2-51 test method (12-channel recording)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3250\" data-end=\"3315\"\u003e\n\u003cp data-start=\"3252\" data-end=\"3268\"\u003eCharging time:\u003c\/p\u003e\n\u003cul data-start=\"3271\" data-end=\"3315\"\u003e\n\u003cli data-start=\"3271\" data-end=\"3315\"\u003e\n\u003cp data-start=\"3273\" data-end=\"3315\"\u003eApproximately 3 hours from empty to full\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3316\" data-end=\"3404\"\u003e\n\u003cp data-start=\"3318\" data-end=\"3341\"\u003eAdditional functions:\u003c\/p\u003e\n\u003cul data-start=\"3344\" data-end=\"3404\"\u003e\n\u003cli data-start=\"3344\" data-end=\"3404\"\u003e\n\u003cp data-start=\"3346\" data-end=\"3404\"\u003eSupports connection to barcode scanner or ID card reader\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Revive Med Lab","offers":[{"title":"Default Title","offer_id":45630076256417,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/9620\/1633\/files\/20260327160550_787_153.jpg?v=1774600177","url":"https:\/\/www.revivemedlab.com\/zh\/products\/twelve-channel-automatic-analysis-electrocardiograph-fx-8322","provider":"Reco Link","version":"1.0","type":"link"}